Alto Professional

CISCO WS-C3560G-24TS-S *15.0 IOS* 24-Port Gigabit Switch *30 Days Warranty

Description: Model Number: CISCO WS-C3560G-24TS-SQuantity Available: Five(5)Quantity: ONE (1)Warranty: 30 DAYS warrantyTEST REPORT SHOW ENVIRONMENT ALL Switch#sh env alFAN is OKSYSTEM TEMPERATURE is OKSystem Temperature Value: 34 Degree CelsiusSystem Temperature State: GREENYellow Threshold : 55 Degree CelsiusRed Threshold : 65 Degree CelsiusSW PID Serial# Status Sys Pwr PoE Pwr Watts--- ------------------ ---------- --------------- ------- ------- ----- 1 Built-in Good SW Status RPS Name RPS Serial# RPS Port#-- ------------- ---------------- ----------- ---------1 Not Present <>SHOW FLASH: Switch#sh flash: Directory of flash:/ 2 drwx 256 Mar 1 1993 00:17:25 +00:00 c3560-ipservicesk9-mz.150-2.SE8 516 -rwx 109 Mar 1 1993 00:27:32 +00:00 info 517 -rwx 1048 Mar 1 1993 00:01:43 +00:00 multiple-fs 32514048 bytes total (10719744 bytes free) SHOW POST Switch#sh postStored system POST messages: Switch 1--------- POST: CPU MIC register Tests : BeginPOST: CPU MIC register Tests : End, Status Passed POST: PortASIC Memory Tests : BeginPOST: PortASIC Memory Tests : End, Status Passed POST: CPU MIC interface Loopback Tests : BeginPOST: CPU MIC interface Loopback Tests : End, Status Passed POST: PortASIC RingLoopback Tests : BeginPOST: PortASIC RingLoopback Tests : End, Status Passed POST: PortASIC CAM Subsystem Tests : BeginPOST: PortASIC CAM Subsystem Tests : End, Status Passed POST: PortASIC Port Loopback Tests : BeginPOST: PortASIC Port Loopback Tests : End, Status Passed SHOW VERSION Switch# sh verCisco IOS Software, C3560 Software (C3560-IPSERVICESK9-M), Version 15.0(2)SE8, RELEASE SOFTWARE (fc1)Technical Support:Copyright (c) 1986-2015 by Cisco Systems, Inc.Compiled Wed 13-May-15 23:32 by prod_rel_team ROM: Bootstrap program is C3560 boot loaderBOOTLDR: C3560 Boot Loader (C3560-HBOOT-M) Version 12.2(44)SE5, RELEASE SOFTWARE (fc1) Switch uptime is 5 minutesSystem returned to ROM by power-onSystem image file is "flash:/c3560-ipservicesk9-mz.150-2.SE8/c3560-ipservicesk9-mz.150-2.SE8.bin" This product contains cryptographic features and is subject to UnitedStates and local country laws governing import, export, transfer anduse. Delivery of Cisco cryptographic products does not implythird-party authority to import, export, distribute or use encryption.Importers, exporters, distributors and users are responsible forcompliance with U.S. and local country laws. By using this product youagree to comply with applicable laws and regulations. If you are unableto comply with U.S. and local laws, return this product immediately. A summary of U.S. laws governing Cisco cryptographic products may be found at: cisco WS-C3560G-24TS (PowerPC405) processor (revision C0) with 131072K bytes of memory.Processor board ID FOC1034Y2DQLast reset from power-on1 Virtual Ethernet interface28 Gigabit Ethernet interfacesThe password-recovery mechanism is enabled. 512K bytes of flash-simulated non-volatile configuration memory.Base ethernet MAC Address : 00:19:2F:AB:4B:80Motherboard assembly number : 73-9708-04Power supply part number : 341-0098-02Motherboard serial number : FOC10341PZQPower supply serial number : AZS103402MHModel revision number : C0Motherboard revision number : A0Model number : WS-C3560G-24TS-SSystem serial number : FOC1034Y2DQSFP Module assembly part number : 73-7757-03SFP Module revision Number : A0SFP Module serial number : CAT10305F4HTop Assembly Part Number : 800-25864-02Top Assembly Revision Number : B0Version ID : V02CLEI Code Number : CNMW200ARBHardware Board Revision Number : 0x05 Switch Ports Model SW Version SW Image------ ----- ----- ---------- ----------* 1 28 WS-C3560G-24TS 15.0(2)SE8 C3560-IPSERVICESK9-M Configuration register is 0xFPORT LOOP-BACK TEST Switch#*Mar 1 00:20:21.146: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/1, changed state to up*Mar 1 00:20:21.188: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/2, changed state to up*Mar 1 00:20:22.153: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/1, changed state to up*Mar 1 00:20:22.194: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/2, changed state to up*Mar 1 00:20:27.362: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/1, changed state to down*Mar 1 00:20:27.798: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/2, changed state to down*Mar 1 00:20:28.369: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/1, changed state to down*Mar 1 00:20:28.796: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/2, changed state to down*Mar 1 00:20:32.236: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/3, changed state to up*Mar 1 00:20:32.278: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/4, changed state to up*Mar 1 00:20:33.242: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/3, changed state to up*Mar 1 00:20:33.284: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/4, changed state to up*Mar 1 00:20:37.017: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/3, changed state to down*Mar 1 00:20:37.445: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/4, changed state to down*Mar 1 00:20:38.032: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/3, changed state to down*Mar 1 00:20:38.443: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/4, changed state to down*Mar 1 00:20:40.003: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/5, changed state to up*Mar 1 00:20:40.029: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/6, changed state to up*Mar 1 00:20:41.010: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/5, changed state to up*Mar 1 00:20:41.035: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/6, changed state to up*Mar 1 00:20:47.369: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/5, changed state to down*Mar 1 00:20:47.797: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/6, changed state to down*Mar 1 00:20:48.367: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/5, changed state to down*Mar 1 00:20:48.795: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/6, changed state to down*Mar 1 00:20:50.221: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/7, changed state to up*Mar 1 00:20:50.271: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/8, changed state to up*Mar 1 00:20:51.227: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/7, changed state to up*Mar 1 00:20:51.278: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/8, changed state to up*Mar 1 00:20:57.284: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/7, changed state to down*Mar 1 00:20:57.703: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/8, changed state to down*Mar 1 00:20:58.282: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/7, changed state to down*Mar 1 00:20:58.702: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/8, changed state to down*Mar 1 00:21:00.522: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/9, changed state to up*Mar 1 00:21:00.539: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/10, changed state to up*Mar 1 00:21:01.529: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/9, changed state to up*Mar 1 00:21:01.545: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/10, changed state to up*Mar 1 00:21:07.216: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/9, changed state to down*Mar 1 00:21:07.594: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/10, changed state to down*Mar 1 00:21:08.214: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/9, changed state to down*Mar 1 00:21:08.592: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/10, changed state to down*Mar 1 00:21:10.026: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/11, changed state to up*Mar 1 00:21:10.043: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/12, changed state to up*Mar 1 00:21:11.033: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/11, changed state to up*Mar 1 00:21:11.050: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/12, changed state to up*Mar 1 00:21:17.576: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/12, changed state to down*Mar 1 00:21:17.962: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/11, changed state to down*Mar 1 00:21:18.583: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/12, changed state to down*Mar 1 00:21:18.960: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/11, changed state to down*Mar 1 00:21:20.520: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/13, changed state to up*Mar 1 00:21:20.537: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/14, changed state to up*Mar 1 00:21:21.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/13, changed state to up*Mar 1 00:21:21.544: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/14, changed state to up*Mar 1 00:21:26.736: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/13, changed state to down*Mar 1 00:21:27.122: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/14, changed state to down*Mar 1 00:21:27.735: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/13, changed state to down*Mar 1 00:21:28.121: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/14, changed state to down*Mar 1 00:21:29.597: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/16, changed state to up*Mar 1 00:21:29.639: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/15, changed state to up*Mar 1 00:21:30.604: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/16, changed state to up*Mar 1 00:21:30.646: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/15, changed state to up*Mar 1 00:21:34.186: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/16, changed state to down*Mar 1 00:21:34.613: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/15, changed state to down*Mar 1 00:21:35.184: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/16, changed state to down*Mar 1 00:21:35.612: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/15, changed state to down*Mar 1 00:21:39.663: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/17, changed state to up*Mar 1 00:21:39.705: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to up*Mar 1 00:21:40.670: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/17, changed state to up*Mar 1 00:21:40.712: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/18, changed state to up*Mar 1 00:21:43.925: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/17, changed state to down*Mar 1 00:21:44.353: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/18, changed state to down*Mar 1 00:21:44.923: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/17, changed state to down*Mar 1 00:21:45.351: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/18, changed state to down*Mar 1 00:21:46.827: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/20, changed state to up*Mar 1 00:21:46.869: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/19, changed state to up*Mar 1 00:21:47.834: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/20, changed state to up*Mar 1 00:21:47.876: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/19, changed state to up*Mar 1 00:21:58.454: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/20, changed state to down*Mar 1 00:21:58.882: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/19, changed state to down*Mar 1 00:21:59.460: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/20, changed state to down*Mar 1 00:21:59.888: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/19, changed state to down*Mar 1 00:22:02.061: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/21, changed state to up*Mar 1 00:22:02.078: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/22, changed state to up*Mar 1 00:22:03.093: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/21, changed state to up*Mar 1 00:22:03.093: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/22, changed state to up*Mar 1 00:22:08.520: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/22, changed state to down*Mar 1 00:22:08.906: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/21, changed state to down*Mar 1 00:22:09.518: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/22, changed state to down*Mar 1 00:22:09.904: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/21, changed state to down*Mar 1 00:22:12.480: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/23, changed state to up*Mar 1 00:22:12.496: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/24, changed state to up*Mar 1 00:22:13.486: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/23, changed state to up*Mar 1 00:22:13.503: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/24, changed state to up*Mar 1 00:22:16.665: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/23, changed state to down*Mar 1 00:22:17.085: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/24, changed state to down*Mar 1 00:22:17.664: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/23, changed state to down*Mar 1 00:22:18.083: %LINK-3-UPDOWN: Interface GigabitEthernet2/0/24, changed state to down SFP GIGABYTE PORTS (TESTED WITH GLC-SX-MM FIBER OPTIC CABLES) Switch#*Mar 1 00:06:01.372: %LINK-3-UPDOWN: Interface GigabitEthernet0/25, changed state to up*Mar 1 00:06:02.379: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/25, changed state to up*Mar 1 00:06:10.524: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/25, changed state to down*Mar 1 00:06:11.523: %LINK-3-UPDOWN: Interface GigabitEthernet0/25, changed state to down*Mar 1 00:06:16.673: %LINK-3-UPDOWN: Interface GigabitEthernet0/26, changed state to up*Mar 1 00:06:17.680: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/26, changed state to up*Mar 1 00:06:20.792: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/26, changed state to down*Mar 1 00:06:21.790: %LINK-3-UPDOWN: Interface GigabitEthernet0/26, changed state to down*Mar 1 00:06:24.768: %LINK-3-UPDOWN: Interface GigabitEthernet0/27, changed state to up*Mar 1 00:06:25.775: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/27, changed state to up*Mar 1 00:06:30.405: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/27, changed state to down*Mar 1 00:06:31.404: %LINK-3-UPDOWN: Interface GigabitEthernet0/27, changed state to down*Mar 1 00:06:41.831: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/28, changed state to up*Mar 1 00:06:42.988: %LINK-3-UPDOWN: Interface GigabitEthernet0/28, changed state to up*Mar 1 00:06:49.858: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/28, changed state to down*Mar 1 00:06:50.857: %LINK-3-UPDOWN: Interface GigabitEthernet0/28, changed state to dow **NOTE FOR BUYER** If you buyer has any problem with product purchase, please contact us immediately we will resolve it quickly, please don't leave OPEN CASE on ebay or leave Negative feedback before contact us.

Price: 74.99 USD

Location: South Hackensack, New Jersey

End Time: 2024-11-17T21:05:06.000Z

Shipping Cost: 0 USD

Product Images

CISCO WS-C3560G-24TS-S *15.0 IOS* 24-Port Gigabit Switch *30 Days WarrantyCISCO WS-C3560G-24TS-S *15.0 IOS* 24-Port Gigabit Switch *30 Days WarrantyCISCO WS-C3560G-24TS-S *15.0 IOS* 24-Port Gigabit Switch *30 Days WarrantyCISCO WS-C3560G-24TS-S *15.0 IOS* 24-Port Gigabit Switch *30 Days WarrantyCISCO WS-C3560G-24TS-S *15.0 IOS* 24-Port Gigabit Switch *30 Days Warranty

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Seller

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money back or replacement (buyer's choice)

Non-Domestic Product: No

Brand: Cisco

Form Factor: Rack-Mountable

Type: Ethernet Switch

Manufacturer Warranty: 1 Month

Custom Bundle: No

Model: WS-C3560G-24TS-S

MPN: WS-C3560G-24TS-S

Modified Item: No

Recommended

Cisco SPA508G 8-Line IP Phone
Cisco SPA508G 8-Line IP Phone

$20.00

View Details
Cisco C3850-NM-2-40G Cisco Catalyst 3850 2x40GE Network Module - Fast Shipping
Cisco C3850-NM-2-40G Cisco Catalyst 3850 2x40GE Network Module - Fast Shipping

$379.99

View Details
(P) Cisco WS-C2960S-48TS-L 48-Port Managed Gigabit Network Switch Pre-Owned
(P) Cisco WS-C2960S-48TS-L 48-Port Managed Gigabit Network Switch Pre-Owned

$36.99

View Details
Cisco ISR4331/K9 Integrated Services Router  ISR4331 New Open Box
Cisco ISR4331/K9 Integrated Services Router ISR4331 New Open Box

$229.99

View Details
Cisco Catalyst WS-C3850-12X48U-S 48P 1GbE 12P 10GbE UPoE 2PSU Switch
Cisco Catalyst WS-C3850-12X48U-S 48P 1GbE 12P 10GbE UPoE 2PSU Switch

$195.00

View Details
Genuine Cisco GLC-GE-100FX 10-2019-02 100Base-FX SFP GBIC Transceiver Module
Genuine Cisco GLC-GE-100FX 10-2019-02 100Base-FX SFP GBIC Transceiver Module

$49.00

View Details
Original Cisco SFP-10G-SR Transceiver Module 10GB 850nm MMF SFP+ 10-2415-03
Original Cisco SFP-10G-SR Transceiver Module 10GB 850nm MMF SFP+ 10-2415-03

$9.99

View Details
Cisco C3850-NM-4-10G Catalyst 3850 Series 4x 10GB SFP+ Switch Module
Cisco C3850-NM-4-10G Catalyst 3850 Series 4x 10GB SFP+ Switch Module

$99.99

View Details
New Cisco SFP-10G-LR-S 10GBASE-LR SFP+ Transceiver Module 1310nm 10km LC SMF
New Cisco SFP-10G-LR-S 10GBASE-LR SFP+ Transceiver Module 1310nm 10km LC SMF

$24.90

View Details
Cisco 24 Ports UPoE Managed Network Switch P/N: C9300-24UX-A Tested Working
Cisco 24 Ports UPoE Managed Network Switch P/N: C9300-24UX-A Tested Working

$314.99

View Details